Cardinal technologies, inc mvp144i Card Type Modem(asynchronous), Fax Chip Set Rockwell Maximum Data Rate 14.4Kbps Maximum Fax Rate 14.4Kbps Data Bus 8-Bit ISA Fax Class Class I Data Modulation Protocol Bell 103A/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis Fax Modulation Protocol ITU-T V.17, V.21CH2, V.27, V.29 Error Correction/Compression MNP2-5, V.42, V.42bis, T.30 [Image] CONNECTIONS Function Label Function Label Line in CN1 Line out CN2 SERIAL PORT ADDRESS Setting JP1 COM1 (3F8h) Pins 1 & 8, 2 & 9 closed COM2 (2F8h) Pins 2 & 9 closed COM3 (3E8h) Pins 1 & 8 closed COM4 (2E8h) Pins 1 & 2 closed INTERRUPT SELECTION Setting JP1 2 Pins 4 & 5, 6 & 13 closed 3 Pins 4 & 11, 5 & 6 closed 4 (COM 1) Pins 3 & 10 closed 4 (COM 2) Pins 3 & 10, 5 & 6 closed 5 Pins 5 & 12, 6 & 7 closed 7 Pins 5 & 6, 7 & 14 closed 9 Pins 4 & 5, 6 & 13 closed Proprietary AT Command Set BACKSPACE CHARACTER Type: Register Format AT [cmds] S5=n [cmds] Default: 8 Range: 0-255 Unit: ASCII Description: Selects a character used for backspace BIT MAPPED REGISTERS Register Default S14 138 S21 4 S22 117 S23 55 S27 74 S28 0 S31 194 S39 3 S40 105 S41 195 DCE LINE SPEED Type: Register Format AT [cmds] S37=n [cmds] Description: Sets the maximum allowable data exchange rate attempted during handshake process. Command Function S37=0 AT command rate S37=3 300bps S37=5 1200bps in V.22 S37=6 2400bps in V.22bis S37=7 1200/75 in V.23 S37=8 4800bps in V.32bis/V.32 S37=9 9600bps in V.32bis/V.32 S37=10 12.0Kbps in V.32bis S37=11 14.4Kbps in V.32bis S37=12 7200bps in V.32bis DIAL Type: Immediate Format: AT [cmds] D<#> [cmds] Description: Dials telephone number according to any modifiers included in the string Note: Any combination of modifiers can be used to produce the desired dial functions in sequence. Command Function DL Re-dial last number DP Pulse dialing enabled DR Answer mode enabled; originate mode disabled following handshake initiation. DS=n Dial stored telephone number n (n=0 to 3) D* Dials star digit D# Dials gate digit DT Tone dialing enabled/Pulse dialing disabled DW Dialing resumed following dial tone detection D, Dialing paused for amount of time specified in S8 register D& Waits for bong tone (At&t) D! Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook. D@ Wait for Quiet Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence of 5 seconds, is received prior to executing the rest of the dial string. D^ Toggles the calling tone for current dialing attempt only D; Modem returned to idle state after dialing. The semicolon can only be placed at the end of the dial command. DTR CHANGE THRESHOLD Type: Register Format AT [cmds] S25=n [cmds] Default: 5 Range: 0-255 Unit: .01 second Description: Sets maximum time a change in the DTR signal will be ignored Note: This is the function of this register when &M1 is not set. ESCAPE SEQUENCE GUARD TIME Type: Register Format AT [cmds] S12=n [cmds] Default: 50 Range: 0-255 Unit: .02 seconds Description: Maximum allowable time between escape character sequence initiation and completion for the escape sequence to be executed. A value of 0 disables guard time. FACTORY DEFAULT PROFILE Type: Configuration Format: AT [cmds] &Fn [cmds] Description: Sets values in active profile to values found in the default profile Command &F0 Restores factory setting 0 &F1 Restores factory setting 1 FLOW CONTROL Type: Configuration Format: AT [cmds] &Kn [cmds] Description: Enables flow control options Command Function &K0 Flow control disabled &K3 RTS/CTS flow control enabled &K4 XON/XOFF flow control enabled &K5 Transparent XON/XOFF flow control enabled &K6 RTS/CTS and XON/XOFF flow control enabled Line modulation Type: Configuration Format: AT [cmds] Fn [cmds] Description: Selects type of modulation used by the modem Command Function F0 Auto-detect mode enabled F1 V.21 or Bell 103 F3 V.32 F4 V.22 at 1200bps or Bell 212A F5 V.22bis F6 V.32bis at 4800bps or V.32 at 4800bps F7 V.32bis at 7200bps F8 V.32bis at 9600bps or V.32 at 9600bps F9 V.32bis at 12.0Kbps F10 V.32bis at 14.4Kbps NO CARRIER TIME-OUT Type: Register Format AT [cmds] S7=n [cmds] Default: 50 Range: 1-255 Unit: 1 second Description: Maximum wait time the modem uses after dialing to detect a carrier signal from the remote modem for both originating and answering calls. Note: W dial modifier also uses S7 to set the maximum time to wait. REPORT INFORMATION Type: Immediate Format: AT [cmds] In [cmds] Description: Displays information requested Command Function I0 Reports modem product code I1 Reports firmware checksum I2 Tests and reports firmware checksum I3 Reports firmware revision I4 Reports Identifier string I5 Reports country code I6 Reports Data Pump modem and revision SLEEP TIMER Type: Register Format AT [cmds] S24=n [cmds] Default: 0 Range: 0-255 Unit: 1 second Description: Maximum duration of DTE and DCE inactivity allowed prior to initiating low-power sleep mode.